CGA Carrier-Grade Analysis designs and manufactures optical power meters, light sources, visual fault locators, optical multimeters, optical spectrum analyzers, eye diagram analyzers, BERT, OTDR, fibe...
Contact online >>
The measurement, control, check and data recording circuits for medium and high power, oil-cooled, oil-insulated electric transformers require bringing current signals outside from the tank.
Protective conductor terminal blocks are subjected in three stages of 1 s each to a current density of 120 A/mm² of the rated cross-section. The requirements are met if, after the test, the individual parts are
After selecting the appropriate current sensing product, the integration of the device must be carefully engineered, thoroughly evaluating all output types, accuracy, measurement range, and
The following chart (and table) can be used to estimate the pulsed current/duty cycle characteristics of contact/cable systems. These guidelines are only estimates as each application is unique and
There are two main ways to measure current – one is based on electromagnetics and is associated with the early moving coil (d''Arsonval) meter, and the other is based on the main theory
If you''re new to dc and low frequency ac calibration, it''s important to understand the impact connectors and cables have on overall measurement uncertainty, as well as the importance of cable maintenance.
This simulates the loading conditions or inducing current in electric circuit up to 4000A. The system is automated, customized to requirements so as to verify
The method, based on real-time high-frequency leakage current measurement, is implemented on a 2.83 kW machine during operation in open-loop configuration.
As with most tasks, there are many ways to terminate motor leads and each one has a following who believe it is the best method. Here we will discuss some of these procedures and outline a few of the
When in heating, the terminal box either maintains minimum airflow or modulates the supply air damper. In order for the terminal box to work properly, the central air-handling unit must provide supply air for
Built-in sweep capabilities use either a source voltage/ measure current or source current/measure voltage test method that can be configured quickly for faster results.
This article focuses on common testing methods for connectors and terminals, including insertion/extraction cycle tests, contact resistance tests, and vibration tests, while delving into the
High-precision power meters (Ge/InGaAs) and stabilized light sources for insertion loss and return loss testing.
Full-featured OTDR, fiber OTDR testers, and modular OTDR test modules for network deployment and troubleshooting.
High-resolution OSA for DWDM and eye diagram testers for signal integrity validation.
BERT up to 800G, fiber endface inspection probes, and extinction ratio meters for comprehensive testing.
We provide custom optical test solutions, from handheld power meters to high-end OSA and BERT systems.
From prototype to mass production, our team ensures premium quality and technical support.
Unit 5, High Tech Business Park, 15 Innovation Drive, Century City, Cape Town, 7441, South Africa
+27 71 539 4287 | +27 71 539 4287 | +86 189 7523 6148 | +86 189 7523 6148 | [email protected]