This Excel template provides a structured relay schedule with columns: Relay Tag, Make & Model, Location, Protected Equipment, Rated Current, CT Ratio, Pickup (Is), TMS, Curve Type (SI/VI/EI/DT), ...
Contact online >>
These spreadsheets below will make your endless calculations much easier!
It includes tables with descriptions of protection functions, actual setting values, and acceptable range of values for different relays protecting components like transformers, generators, and busbars.
Inverter report and associated data: Specific setting requirements to meet all LGIA technical requirements, i.e. reactive current injection, voltage ride through, return from fault delays, etc...
For three-terminal lines where the remote station has no breaker-failure protection, set the relay to reach 110% of the sum of the protected line impedance with infeed and the remote line impedance with the
Dropdown lists for curve type and conditional formatting for overdue test dates are built in. Use this to document all relay settings in a protection coordination study or as a live maintenance register.
Protective relays and devices have been developed over 100 years ago to provide “lastline”of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of
Identify which maintenance method (time-based, performance-based per PRC-005 Attachment A, or a combination) is used to address each Protection System, Automatic Reclosing, and Sudden
This document provides relay setting and coordination calculations for a LPG bottling plant in Gorakhpur, Uttar Pradesh, India. It details the methodology, objectives, and reference documents for
With the help of these spreadsheets below, you can make your endless calculations much easier! Contact us for more information and download:
To determine stability voltage for through fault Vs'' Voltage across the relay at IFS (VS) CT Resistance (RCT)
High-precision power meters (Ge/InGaAs) and stabilized light sources for insertion loss and return loss testing.
Full-featured OTDR, fiber OTDR testers, and modular OTDR test modules for network deployment and troubleshooting.
High-resolution OSA for DWDM and eye diagram testers for signal integrity validation.
BERT up to 800G, fiber endface inspection probes, and extinction ratio meters for comprehensive testing.
We provide custom optical test solutions, from handheld power meters to high-end OSA and BERT systems.
From prototype to mass production, our team ensures premium quality and technical support.
Unit 5, High Tech Business Park, 15 Innovation Drive, Century City, Cape Town, 7441, South Africa
+27 71 539 4287 | +27 71 539 4287 | [email protected]